SUBMERGED BEARING -
FOR CIRCULATING PUMPS
Summary |
 |
The SUBMERGED BEARING
maintains lubrication and increases revolving function for marine.
It is a part which has wear-resistance , including vibration -resistance
, durability in order to maintain funtions for the load support
and vibration of axis
Feature |
 |
¡Û It has superior wear -resistance which is control
a life span.
¡Û It has good durability due to wear - resistance.
¡Û It has heat -resistance.
¡Û It is superior for corrosion resistance compare
to the metal product.
¡Û It is strong for the chemicals of acid and alkali.
¡Û It is light by 50% compare to the specific gravity
of metal
Matter |
 |
SHELL ( SUS316L
)
|
item |
unit |
value |
Physical
Properties
|
hardness(brinell hardness)
|
- |
under 187
|
yield strength
|
kgf/§²
|
over 1700
|
tensile strength
|
kgf/§²
|
over 4800 |
elongation
|
%
|
over 40
|
Chemical
Composition
|
properties |
content(%) |
|
C |
¡Â 0.03 |
|
Si |
¡Â 1.00 |
|
Mn |
¡Â 2.00 |
|
P |
¡Â 0.045 |
|
S |
¡Â 0.030 |
|
Ni |
12~15.00 |
|
Cr |
16~18.00 |
|
Mo |
2~3.00 |
|
RUBBER
( NBR )
|
item |
unit |
value(160¡É¡¿6 minitues ) |
test method |
Physical
Properties
|
specific gravity |
|
1.28
|
ASTM D 6111 |
hardness |
|
79~84 |
Shore A |
100% MODULUS |
kgf/§² |
92 |
ASTM D 3187 |
300% MODULUS |
kgf/§² |
- |
tensile strength |
kgf/§² |
180¡¾50 |
elongation |
% |
260¡¾50 |
tear strength |
kgf/§² |
- |
Silicon
Carbide
|
item |
unit |
value |
test method |
Physical
Properties
|
specific gravity |
- |
3.1¡¾0.5 |
ASTM C 373
|
porosity |
% |
16¡¾2 |
strength at break |
kgf/§² |
over 1326 |
ASTM C 99 |
coefficient of linear
thermal expansion |
¡¿10-6¡É |
4.9 |
ASTM E 289 |
thermal conductivity |
W/m¡¤K |
18 |
ASTM C 201 |
maximum use temperatuer |
¡É |
1525 |
|
Inspection |
 |
Processing
equipment
- MCT MACHING : WIA VX500
- CNC MACHING : SKT 80
Inspection equipment of processing measurement
- SURFACE TABLE : 1000 * 1000
- HEIGHT GAUGE (1/100 ERROR) : 0.01L - 300L
- MICROMETER (1/1000 ERROR) : ¥õ 0.001 - ¥õ 600
- HOLE GAUGE(1/1000 ERROR) : ¥õ 100 - ¥õ 500
- VERNIER CALLIPERS (1/100 ERROR) : 0.01L - 1000L
Inspection of liquid osmotic
(PT inspection)
- first tratment >osmotic treatment > washing treatment >phenomenon
treatment >observation > drying treatment > last treatment
|